Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 17, Issue 7 , Pages 708-716, September 2001

Single– versus two–femoral socket anterior cruciate ligament reconstruction technique:

Biomechanical analysis using a robotic simulator

Department of Orthopaedic Surgery, Osaka University Medical School, Suita; and the Department of Systems and Human Science, Graduate School of Engineering Science, Osaka University, Toyonaka (H.F.), Osaka, Japan

Abstract 

Purpose: Although anterior cruciate ligament (ACL) reconstruction with multistrand autogenous hamstring tendons has been widely performed using a single femoral socket (SS), it is currently advocated to individually reconstruct 2 bundles of the ACL using 2 femoral sockets (TS). However, the difference in biomechanical characteristics between them is unknown. The objective of this study was to clarify their biomechanical differences. Type of Study: This is a cross-over trial using cadaveric knees. Methods: Seven intact human cadaveric knees were mounted in a robotic simulator developed in our laboratory. By applying anterior and posterior tibial load up to ± 100 N at 0°, 15°, 30°, 60°, and 90° of flexion, tibial displacement and load were recorded. After cutting the ACL, the knees underwent ACL reconstruction using TS, followed by that using SS, with 44 or 88 N of initial grafts tension at 20° of flexion. The above-mentioned tests were performed on each reconstructed knee. Results: The tibial displacement in the TS technique was significantly smaller than that in the SS at smaller flexion angles in response to anterior and posterior tibial load of ± 100 N, and the in situ force in the former was significantly greater than that in the latter at smaller flexion angles. Furthermore, in the TS technique, the posterolateral graft acted dominantly in extension, while the anteromedial graft mainly resisted against anterior tibial load in flexion. However, in the SS technique, the anteriorly located graft functioned more predominantly than the posteriorly located graft at all flexion angles. Conclusions: The ACL reconstruction via TS using quadrupled hamstring tendons provides better anterior-posterior stability compared with the conventional reconstruction using a single socket.

Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 17, No 7 (September), 2001: pp 708–716

Keywords:  Anterior cruciate ligament, Hamstring tendon grafts, Two femoral sockets, Single femoral socket, Laxity, Robotic simulator

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Address correspondence and reprint requests to Tatsuo Mae, M.D., Department of Orthopaedic Surgery, Osaka University Medical School, 2-2, Yamada-oka, Suita, Osaka 565-0871, Japan. E-mail: mae@ort.med.osaka-u.ac.jp

PII: S0749-8063(01)36468-X

doi:10.1053/jars.2001.25250

Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 17, Issue 7 , Pages 708-716, September 2001