Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 22, Issue 8 , Pages 820-826 , August 2006

Long-Term Absorption of Poly-L-Lactic Acid Interference Screws

  • F. Alan Barber, M.D.

      Affiliations

    • Plano Orthopedic and Sports Medicine Center, Plano
    • Corresponding Author InformationAddress correspondence and reprint requests to F. Alan Barber, M.D., Plano Orthopedic and Sports Medicine Center, 5228 West Plano Parkway, Plano, Texas 75093, U.S.A.
  • ,
  • W. Dee Dockery, M.D.

      Affiliations

    • American Radiology Associates, Dallas, Texas, U.S.A

References 

  1. Barber FA , Elrod BF , McGuire DA , Paulos LE . Preliminary results of an absorbable interference screw . Arthroscopy . 1995;11:537–548
  2. McGuire DA , Barber FA , Elrod BF , Paulos LE . Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction . Arthroscopy . 1999;15:463–473
  3. Barber FA . Flipped patella tendon autograft ACL reconstruction with Bioscrew fixation . Arthroscopy . 2000;16:483–490
  4. Athanasiou KA , Agrawal CM , Barber FA , Burkhart SS . Orthopaedic applications for PLA-PGA biodegradable polymers . Arthroscopy . 1998;14:726–737
  5. Barber FA . Biology and clinical experience of absorbable materials in ACL fixation . Technique Orthop . 1999;14:34–42
  6. McGuire DA , Barber FA , Milchgrub S , Wolchok JC . A postmortem examination of poly-L lactic acid interference screws 4 months after implantation during anterior cruciate ligament reconstruction . Arthroscopy . 2001;17:988–992
  7. Martinek V , Seil R , Lattermann C , Watkins SC , Fu FH . The fate of the poly-L-lactic acid interference screw after anterior cruciate ligament reconstruction . Arthroscopy . 2001;17:73–76
  8. Stähelin AC , Weiler A , Rufenacht H , Hoffmann R , Geissmann A , Feinstein R . Clinical degradation and biocompatibility of different bioabsorbable interference screws (A report of six cases) . Arthroscopy . 1997;13:238–244
  9. Morgan CD , Gehrmann RM , Jayo MJ , Johnson CS . Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo . Arthroscopy . 2002;18:E47
  10. Weiler A , Hoffmann RFG , Stähelin AC , Helling HJ , Sudkamp NP . Biodegradable implants in sports medicine (The biological base) . Arthroscopy . 2000;16:305–321
  11. Warden WH , Friedman R , Teresi LM , Jackson DW . Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction . Arthroscopy . 1999;15:474–480
  12. Lajtai G, Schmiedhuber G, Unger F, Aitzetmuller G, Klein M, Noszian I, et al. Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction (5-year follow-up) . Arthroscopy . 2001;17:597–602
  13. Lajtai G , Noszian I , Humer K , Unger F , Aitzetmuller G , Orthner E . Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction . Arthroscopy . 1999;15:709–718
  14. Bach FD, Carlier RY, Elis JB, Mompoint DM, Feydy A, Judet O, et al. Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws (MR imaging follow-up) . Radiology . 2002;225:541–550
  15. Lysholm J , Gillquist J . Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale . Am J Sports Med . 1982;10:150–154
  16. Tegner Y , Lysholm J . Rating systems in the evaluation of knee ligament injuries . Clin Orthop . 1985;198:43–49
  17. Noyes FR , Barber SD , Mooar LA . A rationale for assessing sports activity levels and limitations in knee disorders . Clin Orthop . 1989;246:238–249
  18. Anderson AF . Rating scales . In:  Fu FH ,  Harner CD ,  Vince KL editor. Knee surgery . Baltimore: Williams & Wilkins; 1994;p. 275–296
  19. Webster KE , Feller JA , Elliott J , Hutchison A , Payne R . A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction . Arthroscopy . 2004;20:946–950
  20. Buck DC , Simonian PT , Larson RV , Borrow J , Nathanson DA . Timeline of tibial tunnel expansion after single-incision hamstring anterior cruciate ligament reconstruction . Arthroscopy . 2004;20:34–36
  21. Tashman S , Anderst W . In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT (Application to canine ACL deficiency) . J Biomech Eng . 2003;125:238–245
  22. Spruit M , Meijers H , Obradov M , Anderson PG . CT density measurement of bone graft within an intervertebral lumbar cage (Increase of Hounsfield units as an indicator for increasing bone mineral content) . J Spinal Disord Tech . 2004;17:232–235
  23. Weir NA , Buchanan FJ , Orr JF , Dickson GR . Degradation of poly-L-lactide. Part 1. In vitro and in vivo physiological temperature degradation . Proc Inst Mech Eng [H] . 2004;218:307–319
  24. Renouf-Glauser AC , Rose J , Farrar DF , Cameron RE . The effect of crystallinity on the deformation mechanism and bulk mechanical properties of PLLA . Biomaterials . 2005;26:5771–5782
  25. Rothen-Weinhold A, Besseghir K, Vuaridel E, Sublet E, Oudry N, Kubel F, et al. Injection-molding versus extrusion as manufacturing technique for the preparation of biodegradable implants . Eur J Pharm Biopharm . 1999;48:113–121
  26. Kaeding C , Farr J , Kavanaugh T , Pedroza A . A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws . Arthroscopy . 2005;21:147–151
  27. Barber FA , Spruill B , Sheluga M . The effect of outlet fixation on tunnel widening . Arthroscopy . 2003;19:485–492

 This study was supported in part by a grant from the Arthrex Corporation.

PII: S0749-8063(06)00610-4

doi: 10.1016/j.arthro.2006.04.096

Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 22, Issue 8 , Pages 820-826 , August 2006