« Previous
Next »
Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 3
, Pages 351-357
, March 2010
Evaluation of a New Femoral Fixation Device in a Simulated Anterior Cruciate Ligament Reconstruction
References
- . Accelerated rehabilitation after anterior cruciate ligament reconstruction. Am J Sports Med. 1990;18:292–299
- . Graft fixation in cruciate ligament reconstruction. Am J Sports Med. 2000;28:761–774
- . Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: A biomechanical analysis. Arthroscopy. 2006;22:660–668
- . The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis. 2006;63:156–157
- . The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system. Arthroscopy. 1997;13:177–182
- . Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation. Knee Surg Sports Traumatol Arthrosc. 1999;7:215–219
- . Failure of osteointegration of hamstring tendon autograft after anterior cruciate ligament reconstruction. Arthroscopy. 2004;20:424–428
- . Integration of hamstring tendon graft with bone in reconstruction of the anterior cruciate ligament. Arthroscopy. 1997;13:641–643
- . Hamstring insertion site healing after anterior cruciate ligament reconstruction in patients with symptomatic hardware or repeat rupture: A histologic study in 12 patients. Arthroscopy. 2003;19:948–954
- . Twisting and braiding reduces the tensile strength and stiffness of human hamstring tendon grafts used for anterior cruciate ligament reconstruction. Am J Sports Med. 2003;31:861–867
- . A serrated jaw clamp for tendon gripping. Med Eng Phys. 2006;28:379–382
- . Dual cryogenic fixation for mechanical testing of soft musculoskeletal tissues. IEEE Trans Biomed Eng. 2005;52:1792–1795
- . Determinants of cruciate-ligament loading during rehabilitation exercise. Clin Biomech. 1998;13:403–413
- . Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction. Am J Sports Med. 2004;32:635–640
Supported by ConMed Linvatec. The authors report no conflict of interest.
PII: S0749-8063(09)00772-5
doi: 10.1016/j.arthro.2009.08.016
© 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 3
, Pages 351-357
, March 2010