Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 3 , Pages 351-357 , March 2010

Evaluation of a New Femoral Fixation Device in a Simulated Anterior Cruciate Ligament Reconstruction

  • Andrew Speirs, M.A.Sc.

      Affiliations

    • Orthopaedic Biomechanics Laboratory, University of Ottawa, Ottawa, Ontario, Canada
  • ,
  • David Simon, M.D.

      Affiliations

    • Division of Orthopaedic Surgery, University of Ottawa, Ottawa, Ontario, Canada
  • ,
  • Peter Lapner, M.D., F.R.C.S.C.

      Affiliations

    • Division of Orthopaedic Surgery, University of Ottawa, Ottawa, Ontario, Canada
    • Corresponding Author InformationAddress correspondence and reprint requests to Peter Lapner, M.D., F.R.C.S.C., Ottawa Hospital, General Campus, CCW 1648, Box 502, 501 Smyth Rd, Ottawa, Ontario K1H 8L6, Canada

Received 19 November 2008 ,Accepted 24 August 2009.

References 

  1. Shelbourne KD, Nitz P. Accelerated rehabilitation after anterior cruciate ligament reconstruction. Am J Sports Med. 1990;18:292–299
  2. Brand J, Weiler A, Caborn DN, Brown CH, Johnson DL. Graft fixation in cruciate ligament reconstruction. Am J Sports Med. 2000;28:761–774
  3. Milano G, Mulas PD, Ziranu F, Piras S, Manunta A, Fabbriciani C. Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: A biomechanical analysis. Arthroscopy. 2006;22:660–668
  4. Bravman J, Ishak C, Gelber J, Namkoong S, Jazrawi LM, Kummer FJ. The interaction between the whipstitch sutures of multi-strand ACL grafts and interference screw fixation. Bull Hosp Jt Dis. 2006;63:156–157
  5. Ishibashi Y, Rudy TW, Livesay GA, Stone JD, Fu FH, Woo SL. The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system. Arthroscopy. 1997;13:177–182
  6. Höher J, Livesay GA, Ma CB, Withrow JD, Fu FH, Woo SL. Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation. Knee Surg Sports Traumatol Arthrosc. 1999;7:215–219
  7. Song EK, Rowe SM, Chung JY, Moon ES, Lee KB. Failure of osteointegration of hamstring tendon autograft after anterior cruciate ligament reconstruction. Arthroscopy. 2004;20:424–428
  8. Pinczewski LA, Clingeleffer AJ, Otto DD, Bonar SF, Corry IS. Integration of hamstring tendon graft with bone in reconstruction of the anterior cruciate ligament. Arthroscopy. 1997;13:641–643
  9. Robert H, Es-Sayeh J, Heymann D, Passuti N, Eloit S, Vaneenoge E. Hamstring insertion site healing after anterior cruciate ligament reconstruction in patients with symptomatic hardware or repeat rupture: A histologic study in 12 patients. Arthroscopy. 2003;19:948–954
  10. Kim DH, Wilson DR, Hecker AT, Jung TM, Brown CH. Twisting and braiding reduces the tensile strength and stiffness of human hamstring tendon grafts used for anterior cruciate ligament reconstruction. Am J Sports Med. 2003;31:861–867
  11. Cheung JT, Zhang M. A serrated jaw clamp for tendon gripping. Med Eng Phys. 2006;28:379–382
  12. Ramachandran N, Koike Y, Poitras P, Backman D, Uhthoff HK, Trudel G. Dual cryogenic fixation for mechanical testing of soft musculoskeletal tissues. IEEE Trans Biomed Eng. 2005;52:1792–1795
  13. Shelburne KB, Pandy MG. Determinants of cruciate-ligament loading during rehabilitation exercise. Clin Biomech. 1998;13:403–413
  14. Ahmad CS, Gardner TR, Groh M, Arnouk J, Levine WN. Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction. Am J Sports Med. 2004;32:635–640

 Supported by ConMed Linvatec. The authors report no conflict of interest.

PII: S0749-8063(09)00772-5

doi: 10.1016/j.arthro.2009.08.016

Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 3 , Pages 351-357 , March 2010