« Previous
Next »
Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 6
, Pages 729-733
, June 2010
The Effect of a Sequential Compression Device on Hemodynamics in Arthroscopic Shoulder Surgery Using Beach-Chair Position
References
- . Cerebral ischemia during shoulder surgery in the upright position: A case series. J Clin Anesth. 2005;17:463–469
- Effects of the sitting position on the distribution of blood volume in patients undergoing neurosurgical procedures. Br J Anaesth. 2000;84:354–357
- . Anesthesia and surgery in the seated position: Analysis of 554 cases. Neurosurgery. 1985;17:695–702
- . Comparison of surgical and anesthetic complications in neurosurgical patients experiencing venous air embolism in the sitting position. Neurosurgery. 1986;18:157–161
- . Cardiovascular responses in the seated position—Impact of four anesthetic techniques. Anesth Analg. 1983;62:648–653
- . Sequential compression device with thigh-high sleeves supports mean arterial pressure during caesarean section under spinal anaesthesia. Br J Anaesth. 2003;91:695–698
- . Hemodynamic alterations in venous blood flow produced by external pneumatic compression. J Cardiovasc Surg. 1993;34:441–447
- . Intermittent sequential pneumatic compression of the legs in the prevention of venous stasis and postoperative deep vein thrombosis. Surgery. 1980;87:69–76
- . Avoiding catastrophic complications of stroke and death related to shoulder surgery in the sitting position. Arthroscopy. 2008;24:481–482
- . Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med. 2007;35:1904–1909
- . Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth. 2007;99:329–336
- . Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth. 2007;21:3–7
- . Hemodynamic effects of intermittent pneumatic compression of the legs. Anesthesiology. 1987;67:266–268
- . Posture, blood velocity in common femoral vein, and prophylaxis of venous thromboembolism. Lancet. 1995;345:419–421
- . The efficacy of the new SCD response compression system in the prevention of venous stasis. J Vasc Surg. 2000;32:932–940
Supported by Yonsei University Research Fund of 2008. Presented in part at the American Society of Anesthesiologists Annual Meeting, New Orleans, 2009.
The authors report no conflict of interest.
PII: S0749-8063(09)00834-2
doi: 10.1016/j.arthro.2009.10.001
© 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 6
, Pages 729-733
, June 2010