Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 9, Supplement , Pages S35-S40 , September 2010

Stiffer Fixation of the Tibial Double-Tunnel Anterior Cruciate Ligament Complex Versus the Single Tunnel: A Biomechanical Study

  • Duncan E. Meuffels, M.D.

      Affiliations

    • Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
    • Corresponding Author InformationAddress correspondence and reprint requests to Duncan E. Meuffels, M.D., Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, PO Box 2040, 3000 CA Rotterdam, The Netherlands
  • ,
  • Pieter T. Docter, M.Sc.

      Affiliations

    • Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
  • ,
  • Roland A. van Dongen, M.Sc.

      Affiliations

    • Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
  • ,
  • Gert-Jan Kleinrensink, Ph.D.

      Affiliations

    • Department of Neuroscience, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
  • ,
  • Jan A.N. Verhaar, M.D., Ph.D.

      Affiliations

    • Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
  • ,
  • Max Reijman, Ph.D.

      Affiliations

    • Department of Orthopaedic Surgery, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands

Received 1 June 2009 ,Accepted 19 January 2010.

References 

  1. Petersen W, Zantop T. Anatomy of the anterior cruciate ligament with regard to its two bundles. Clin Orthop Relat Res. 2007;454:35–47
  2. Yagi M, Wong EK, Kanamori A, Debski RE, Fu FH, Woo SL. Biomechanical analysis of an anatomic anterior cruciate ligament reconstruction. Am J Sports Med. 2002;30:660–666
  3. Petersen W, Tretow H, Weimann A, et al. Biomechanical evaluation of two techniques for double-bundle anterior cruciate ligament reconstruction: One tibial tunnel versus two tibial tunnels. Am J Sports Med. 2007;35:228–234
  4. Zantop T, Kubo S, Petersen W, Musahl V, Fu FH. Current techniques in anatomic anterior cruciate ligament reconstruction. Arthroscopy. 2007;23:938–947
  5. Lehmann A, Osada N, Zantop T, Raschke M, Petersen W. Femoral bridge stability in double-bundle ACL reconstruction: Impact of bridge width and different fixation techniques on the structural properties of the graft/femur complex. Arch Orthop Trauma Surg. 2009;129:1127–1132
  6. Brand J, Weiler A, Caborn DN, Brown CH, Johnson DL. Graft fixation in cruciate ligament reconstruction. Am J Sports Med. 2000;28:761–774
  7. Kousa P, Jarvinen TL, Vihavainen M, Kannus P, Jarvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction (Part II: Tibial site). Am J Sports Med. 2003;31:182–188
  8. Brand JC, Pienkowski D, Steenlage E, Hamilton D, Johnson DL, Caborn DN. Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am J Sports Med. 2000;28:705–710
  9. Vuori I, Heinonen A, Sievanen H, Kannus P, Pasanen M, Oja P. Effects of unilateral strength training and detraining on bone mineral density and content in young women: A study of mechanical loading and deloading on human bones. Calcif Tissue Int. 1994;55:59–67
  10. Yamanaka M, Yasuda K, Tohyama H, Nakano H, Wada T. The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions. Am J Sports Med. 1999;27:772–777
  11. Lee CH, Huang GS, Chao KH, Wu SS, Chen Q. Differential pretensions of a flexor tendon graft for anterior cruciate ligament reconstruction: A biomechanical comparison in a porcine knee model. Arthroscopy. 2005;21:540–546
  12. Zhang AL, Lewicky YM, Oka R, Mahar A, Pedowitz R. Biomechanical analysis of femoral tunnel pull-out angles for anterior cruciate ligament reconstruction with bioabsorbable and metal interference screws. Am J Sports Med. 2007;35:637–642
  13. Nakano H, Yasuda K, Tohyama H, Yamanaka M, Wada T, Kaneda K. Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction—Biomechanical evaluation with cyclic elongation. Clin Biomech. 2000;15:188–195
  14. Espejo-Baena A, Ezquerro F, de la Blanca AP, Serrano-Fernandez J, Nadal F, Montanez-Heredia E. Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: An in vitro animal study. Arthroscopy. 2006;22:433–440
  15. Walsh MP, Wijdicks CA, Armitage BM, Westerhaus BD, Parker JB, Laprade RF. The 1:1 versus the 2:2 tunnel-drilling technique: Optimization of fixation strength and stiffness in an all-inside double-bundle anterior cruciate ligament reconstruction—A biomechanical study. Am J Sports Med. 2009;37:1539–1547
  16. Meuffels DE, Niggebrugge MJ, Verhaar JA. Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks. Knee Surg Sports Traumatol Arthrosc. 2009;17:135–139
  17. Papachristou G, Kalliakmanis A, Papachristou K, Magnissalis E, Sourlas J, Plessas S. Comparison of fixation methods of double-bundle double-tibial tunnel ACL reconstruction and double-bundle single-tunnel technique. Int Orthop. 2008;32:483–488
  18. Bartz RL, Mossoni K, Tyber J, Tokish J, Gall K, Siparsky PN. A biomechanical comparison of initial fixation strength of 3 different methods of anterior cruciate ligament soft tissue graft tibial fixation: Resistance to monotonic and cyclic loading. Am J Sports Med. 2007;35:949–954
  19. Rupp S, Hopf T, Hess T, Seil R, Kohn DM. Resulting tensile forces in the human bone-patellar tendon-bone graft: Direct force measurement in vitro. Arthroscopy. 1999;15:179–184
  20. Walsh MP, Wijdicks CA, Parker JB, Hapa O, LaPrade RF. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: A biomechanical study in a porcine model. Am J Sports Med. 2009;37:160–167
  21. Seil R, Rupp S, Krauss PW, Benz A, Kohn DM. Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med. 1998;26:815–819
  22. Dargel J, Schmidt-Wiethoff R, Schmidt J, Koebke J. Histomorphology and microradiography of quadriceps tendon-patellar bone grafts in press-fit anterior cruciate ligament reconstruction. J Orthop Res. 2005;23:1206–1210
  23. Magen HE, Howell SM, Hull ML. Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med. 1999;27:35–43
  24. Beynnon BD, Amis AA. In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg Sports Traumatol Arthrosc. 1998;6(Suppl 1):S70–S76
  25. Woo SL, Orlando CA, Camp JF, Akeson WH. Effects of postmortem storage by freezing on ligament tensile behavior. J Biomech. 1986;19:399–404
  26. Park DK, Fogel HA, Bhatia S, et al. Tibial fixation of anterior cruciate ligament allograft tendons: Comparison of 1-, 2-, and 4-stranded constructs. Am J Sports Med. 2009;37:1531–1538

 The authors report no conflict of interest.

PII: S0749-8063(10)00089-7

doi: 10.1016/j.arthro.2010.01.018

Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 26, Issue 9, Supplement , Pages S35-S40 , September 2010