Volume 28, Issue 2 , Pages 247-254, February 2012
Biomechanics of the Human Triple-Bundle Anterior Cruciate Ligament
Purpose
To investigate the biomechanics of the intermediate (IM), anteromedial (AM), and posterolateral (PL) bundles in the human anterior cruciate ligament (ACL).
Methods
Eighteen human cadaveric knees were tested with a robotic/universal force-moment sensor testing system. Anterior tibial translation (ATT) was determined under an 89-N anterior tibial load. Coupled ATT was determined under a combined rotatory load of 7-Nm valgus and 5-Nm internal rotation torque (pivot moment). Each bundle's in situ forces were measured under identical external loading conditions.
Results
Under anterior load, the PL bundle's in situ force was highest at 0° and decreased during flexion. Under the anterior load, the AM bundle's in situ force was significantly higher than the IM and PL bundles' force at 15°, 30°, and 60°. Under the pivot moment, the AM bundle's in situ force was significantly higher than the PL and IM bundles' force at 0° and 15°, and the IM bundle had the lowest in situ force at 0° but higher in situ force than the AM and PL bundles at 30° and 45°. IM and AM bundle removal increased ATT under the anterior load at all angles. Cutting the PL bundle after IM and AM bundle removal (whole ACL removal) significantly increased ATT under the anterior load at 0°, 15°, and 30° of knee flexion and increased coupled ATT under the pivot moment at 0° and 15°.
Conclusions
The biomechanical role of each of the 3 ACL bundles (AM, IM, and PL) was measured with a robotic/universal force-moment sensor testing system. The AM bundle stabilized the knee against both the anterior and rotatory loads. The PL bundle stabilized the knee especially near full extension. The IM bundle supported the AM and PL bundles through all flexion angles, especially from 30° to 45°, against the rotatory load.
Clinical Relevance
Knowledge of functions of the different ACL bundles will help improve ACL reconstruction techniques to enable restoration of normal knee function.
To access this article, please choose from the options below
Supported by the Albert B. Ferguson Jr., M.D., Orthopaedic Fund of The Pittsburgh Foundation. F.H.F. received a research grant from Smith & Nephew.
The authors report no conflict of interest.
PII: S0749-8063(11)00996-0
doi:10.1016/j.arthro.2011.07.019
© 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Volume 28, Issue 2 , Pages 247-254, February 2012