Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 12, Issue 2 , Pages 187-192, April 1996

Accuracy of femoral tunnel placement and resulting graft force using one- or two-incision drill guides. A cadaver study on ten paired knees

  • Torbjørn Grøntvedt, M.D.

      Affiliations

    • Corresponding Author InformationAddress correspondence and reprint requests to Torbjørn Grøntvedt, M.D., Department of Orthopaedics, Trondheim University Hospital, 7006 Trondheim, Norway.
    • Department of Orthopaedics, Trondheim University Hospital, Trondheim, Norway (T.G.)
    • Bioengineering Laboratory, Department of Orthopaedics, University of Minnesota, Minneapolis, MN, U.S.A. (F. P., L. E.)
  • ,
  • Fernando Pena, M.D.

      Affiliations

    • Department of Orthopaedics, Trondheim University Hospital, Trondheim, Norway (T.G.)
    • Bioengineering Laboratory, Department of Orthopaedics, University of Minnesota, Minneapolis, MN, U.S.A. (F. P., L. E.)
  • ,
  • Lars Engebretsen, M.D., Ph.D.

      Affiliations

    • Department of Orthopaedics, Trondheim University Hospital, Trondheim, Norway (T.G.)
    • Bioengineering Laboratory, Department of Orthopaedics, University of Minnesota, Minneapolis, MN, U.S.A. (F. P., L. E.)

Abstract 

Recently, one-incision drill guides introduced through predilled tibial tunnels have become popular in anterior cruciate ligament (ACL) reconstruction. No data are available on the reproducibility of the tunnel placement when this drill guide is used. The primary goal of this study was to compare accuracy of tunnel placement using the one-inciscion (all-inside) and the conventional two-incision drill guide (outside-in) to the location of the center of the normal ACL attachment. Furthermore, our goal was to measure the forces seen by the normal ACL during extension from 90° of flexion, when the tibia is subjected to 100 N anterior load (22.7 lbs), and compare these with the forces measured in the reconstructions performed with the two drill guides. The center of the tunnel on the lateral femoral condyle using the two different drill guides was measured with a three-dimensional pointer and compared with the center of the normal ACL insertion site. Forces in the normal ACL and the reconstructed ligament were measured with a buckle transducer in a loaded and an unloaded state at four different flexion angles. The one-incision drill guide led to a statistically more proximal placement of the graft than both the conventional drill guide and the center of the normal ACL. Both drill guides led to an anterior placement compared with the normal ACL. There was no difference in the graft forces after reconstruction with the two drill guides, but the forces in the loaded grafts were twice those of the normal ACL.

Keywords:  Anterior cruciate ligament, Drill guides, Graft forces

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0749-8063(96)90009-2

Arthroscopy: The Journal of Arthroscopic and Related Surgery
Volume 12, Issue 2 , Pages 187-192, April 1996