Advertisement
Original Articles| Volume 17, ISSUE 5, P439-444, May 2001

Download started.

Ok

Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus

      Abstract

      Purpose: The use of biodegradable implants for arthroscopic repair of meniscal lesions is becoming increasingly popular. The aim of this study was to test the biomechanical stability and the mode of failure of these implants. Type of Study: Biomechanical testing study. Methods: Biomechanical investigations were performed on human menisci using 6 commonly used biodegradable implants for meniscal repair to compare them with horizontal mattress suture using 2/0 Ethibond (Ethicon, Norderstedt, Germany). Included in this study were the Meniscus Arrow (Bionx, Tampere, Finland), Dart (Arthrex, Naples, FL), Stinger (Linvatec, Largo, FL), Meniscal Screw (Innovasive, Marlborough, MA), T-Fix (Acufex, Mansfield, MA), and the Fastener (Mitek, Westwood, MA). The tests were carried out using a material testing machine at a loading rate of 10 N/second. The ultimate tension load (UTL), elongation, and stiffness were evaluated for each implant technique. Results: The highest UTL was shown by Ethibond (62 ± 7.91 N) and the T-Fix (51.35 ± 16.31 N), followed by the Fastener (32.67 ± 2.97 N). All other implants had a significantly lower UTL (P =.001). Less elongation under a load of 5 N was noted for Ethibond (0.64 ± 0.25 mm) and for T-Fix (0.43 ± 0.32 mm) compared with the other implants. The greatest elongation was found for the Fastener (2.239 ± 0.581 mm). The stiffness of the fixation was similar in all implants, except for the Dart and Fastener, which were significantly inferior (P <.05). Conclusions: All of the biodegradable implants had lower UTL than the suture techniques. Therefore, when using the implants, they should be inserted close together to provide sufficient stability. In cases of an extended lesion, there might even be an option to combine the implant and suturing techniques.
      Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 17, No 5 (May-June), 2001: pp 439–444

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Arthroscopy
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Allen PR
        • Denham RA
        • Swan AV
        Late degenerative changes after meniscectomy. Factors affecting the knee after operation.
        J Bone Joint Surg Br. 1984; 66: 666-671
        • Bourne RB
        • Finlay JB
        • Papadopoulos P
        • Andreae P
        The effect of medial meniscectomy on strain distribution in the proximal part of the tibia.
        J Bone Joint Surg Am. 1984; 66: 1431-1437
        • Ihn JC
        • Kim SJ
        • Park IH
        In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy.
        Int Orthop. 1993; 17: 214-218
        • Lanzer WL
        • Komenda G
        Changes in articular cartilage after meniscectomy.
        Clin Orthop. 1990; 252: 41-48
        • Levy IM
        • Torzilli PA
        • Warren RF
        The effect of medial meniscectomy on anterior-posterior motion of the knee.
        J Bone Joint Surg Am. 1982; 64: 883-888
        • Messner K
        • Gao J
        The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment.
        J Anat. 1998; 193: 161-178
        • Cooper DE
        • Arnoczky SP
        • Warren RF
        Meniscal repair.
        Clin Sports Med. 1991; 10: 529-548
        • Arnoczky SP
        • Warren RF
        The microvasculature of the meniscus and its response to injury. An experimental study in the dog.
        Am J Sports Med. 1983; 11: 131-141
        • Newman AP
        • Daniels AU
        • Burks RT
        Principles and decision making in meniscal surgery.
        Arthroscopy. 1993; 9: 33-51
        • Rodeo SA
        • Warren RF
        Meniscal repair using the outside-to-inside technique.
        Clin Sports Med. 1996; 15: 469-481
        • van Trommel MF
        • Simonian PT
        • Potter HG
        • Wickiewicz TL
        Different regional healing rates with the outside-in technique for meniscal repair.
        Am J Sports Med. 1998; 26: 446-452
        • Leenslag JW
        • Pennings AJ
        • Bos RR
        • Rozema FR
        • Boering G
        Resorbable materials of poly(L-lactide). VII. In vivo and in vitro degradation.
        Biomaterials. 1987; 8: 311-314
        • Morgan CD
        • Wojtys EM
        • Casscells CD
        • Casscells SW
        Arthroscopic meniscal repair evaluated by second-look arthroscopy.
        Am J Sports Med. 1991; 19: 632-637
        • Arnoczky SP
        Building a meniscus. Biologic considerations.
        Clin Orthop. 1999; : S244-S253
        • Takahashi M
        • Suzuki M
        • Kushida K
        • Hoshino H
        • Inoue T
        The effect of aging and osteoarthritis on the mature and senescent cross-links of collagen in human meniscus.
        Arthroscopy. 1998; 14: 366-372
        • Wirth CJ
        • Rodriguez M
        • Miachowski KA
        Meniskusnaht–Meniskusersatz.
        : Georg Thieme Verlag, Stuttgart1988
        • Kohn D
        • Siebert W
        Meniscus suture techniques: A comparative biomechanical cadaver study.
        Arthroscopy. 1989; 5: 324-327
        • Rimmer MG
        • Nawana NS
        • Keene GC
        • Pearcy MJ
        Failure strengths of different meniscal suturing techniques.
        Arthroscopy. 1995; 11: 146-150
        • Dervin GF
        • Downing KJ
        • Keene GC
        • McBride DG
        Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study.
        Arthroscopy. 1997; 13: 296-300
        • Post WR
        • Akers SR
        • Kish V
        Load to failure of common meniscal repair techniques: Effects of suture technique and suture material.
        Arthroscopy. 1997; 13: 731-736
        • Albrecht-Olsen P
        • Kristensen G
        • Tormala P
        Meniscus bucket-handle fixation with an absorbable Biofix tack: Development of a new technique.
        Knee Surg Sports Traumatol Arthrosc. 1993; 1: 104-106
        • Aspden RM
        • Yarker YE
        • Hukins DW
        Collagen orientations in the meniscus of the knee joint.
        J Anat. 1985; 140: 371-380
        • Beaupre A
        • Choukroun R
        • Guidouin R
        • et al.
        [A study of the menisci of the knee by scanning electron microscopy].