Abstract
One of the most discussed subjects regarding anterior cruciate ligament (ACL) repair
methods is femoral fixation. One of the materials often used for fixation in recent
years is the EndoButton (Acufex Microsurgical, Mansfield, MA), which provides rapid
and secure fixation. Although many reports about femoral fixation with EndoButton
have been published, insufficient information is available on possible complications.
We have used 240 EndoButtons in our clinic for ACL repairs since 1997. The goal of
this study was to report a case of ACL repair with an EndoButton, in which we experienced
a complication. In this case, the EndoButton dropped into the knee joint after 2 years.
Keywords
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to ArthroscopyAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- EndoButton endoscopic fixation technique in anterior cruciate ligament reconstruction.Arthroscopy. 1995; 11: 340-343
- Potential pitfalls of Kurosaka screw interference fixation for anterior cruciate ligament surgery.Am J Sports Med. 1989; 2: 76-82
- Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction.Arthroscopy. 1989; 5: 225-226
- Tunnel expansion after hamstring anterior cruciate ligament reconstruction with 1-incision EndoButton femoral fixation.Arthroscopy. 2000; 16: 707-714
- Arthroscopic posterior cruciate ligament reconstruction using hamstring tendons.Arthroscopy. 1996; 12: 638-642
- Tripled semitendinosus anterior cruciate ligament reconstruction with EndoButton fixation.Acta Orthop Scand. 2000; 71: 381-386
- Potantial pitfall of the EndoButton.Arthroscopy. 1998; 14: 66-69
- Intra-articular detachment of the more than 18 months after anterior cruciate ligament reconstruction.Arthroscopy. 1999; 15: 775-778
- EndoButton drill bit failure.Arthroscopy. 2002; 18: 322-324
- An unidentified pitfall of EndoButton use.Knee Surg Sports Traumatol Arthrosc. 2002; 10: 247-249
Article info
Identification
Copyright
© 2004 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.