Rotator Cuff Tendon Repair Morphology Comparing 2 Single-Anchor Repair Techniques

      Purpose

      To compare the effect of 2 common rotator cuff repair techniques, for smaller tears limited to the use of a single anchor, on tendon morphology in relation to the footprint.

      Methods

      Six matched pairs of human shoulders were dissected, and a standardized 10-mm supraspinatus tendon tear was created. Two single-anchor repairs were performed: simple repair with the anchor on the footprint or inverted-mattress repair with the anchor 1 cm distal-lateral to the footprint. The repaired specimens were frozen in situ with liquid nitrogen. Coronal cross sections through the intact and repaired tendon were made. A digitizer was used to measure variables including tendon area and radius of tendon curvature.

      Results

      Comparing between repairs, we found significantly more gap formation for the simple repair at the repair cross section (3.67 ± 0.32 mm v 0.68 ± 0.10 mm, P = .00050). The simple repair had less tendon area (38.28 ± 2.50 mm2 v 58.65 ± 4.06 mm2, P = .0036) and a smaller radius of curvature (8.47 ± 1.39 mm v 32.51 ± 3.94 mm, P = .0046). For the simple repair, there was significantly more gap formation, less tendon area, and a smaller radius of tendon curvature for all repair cross sections compared with the intact cross sections (P < .05). For the inverted-mattress repair, there was more gap formation compared with the intact condition (P < .05), although it was less than 1 mm on average; for tendon area, radius of curvature, and tendon height, the cross section centered on the repair showed no differences compared with the intact control.

      Conclusions

      For rotator cuff tears that are 10 mm or smaller and limited to the use of a single anchor, using a distal-lateral anchor position with tape-type suture can provide better maintenance of native tendon morphology and footprint dimensions when compared with repair that uses standard sutures and places the anchor on the footprint.

      Clinical Relevance

      For smaller tears, the inverted-mattress repair described in this article may provide a relatively improved healing environment compared with a simple repair on the footprint, potentially optimizing the prevention of early tear progression.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Arthroscopy
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Kamath G.
        • Galatz L.M.
        • Keener J.D.
        • Teefey S.A.
        • Middleton W.
        • Yamaguchi K.
        Tendon integrity and functional outcome after arthroscopic repair of high-grade partial-thickness supraspinatus tears.
        J Bone Joint Surg Am. 2009; 91: 1055-1062
        • Oh J.H.
        • Oh C.H.
        • Kim S.H.
        • Kim J.H.
        • Yoon J.P.
        • Jung J.H.
        Clinical features of partial anterior bursal-sided supraspinatus tendon (PABST) lesions.
        J Shoulder Elbow Surg. 2012; 21: 295-303
        • Koh K.H.
        • Shon M.S.
        • Lim T.K.
        • Yoo J.C.
        Clinical and magnetic resonance imaging results of arthroscopic full-layer repair of bursal-side partial-thickness rotator cuff tears.
        Am J Sports Med. 2011; 39: 1660-1667
        • Oh J.H.
        • Jun B.J.
        • McGarry M.H.
        • Lee T.Q.
        Does a critical rotator cuff tear stage exist? A biomechanical study of rotator cuff tear progression in human cadaver shoulders.
        J Bone Joint Surg Am. 2011; 93: 2100-2109
        • Yamaguchi K.
        • Ditsios K.
        • Middleton W.D.
        • Hildebolt C.F.
        • Galatz L.M.
        • Teefey S.A.
        The demographic and morphological features of rotator cuff disease. A comparison of asymptomatic and symptomatic shoulders.
        J Bone Joint Surg Am. 2006; 88: 1699-1704
        • Kim H.M.
        • Dahiya N.
        • Teefey S.A.
        • et al.
        Location and initiation of degenerative rotator cuff tears: An analysis of three hundred and sixty shoulders.
        J Bone Joint Surg Am. 2010; 92: 1088-1096
        • Wolff A.B.
        • Sethi P.M.
        • Sutton K.M.
        • Covey A.S.
        • Magit D.P.
        • Medvecky M.
        Partial-thickness rotator cuff tears.
        J Am Acad Orthop Surg. 2006; 14: 715-725
        • Park M.C.
        • Pirolo J.M.
        • Park C.J.
        • McGarry M.H.
        • Tibone J.E.
        • Lee T.Q.
        The effect of abduction and rotation on footprint contact for single-row, double-row, and transosseous-equivalent rotator cuff repair techniques.
        Am J Sports Med. 2009; 37: 1599-1608
        • Park M.C.
        • Jun B.J.
        • Park C.J.
        • Ahmad C.S.
        • ElAttrache N.S.
        • Lee T.Q.
        The biomechanical effects of dynamic external rotation on rotator cuff repair compared to testing with the humerus fixed.
        Am J Sports Med. 2007; 35: 1931-1939
        • Kowalsky M.S.
        • Dellenbaugh S.G.
        • Erlichman D.B.
        • Gardner T.R.
        • Levine W.N.
        • Ahmad C.S.
        Evaluation of suture abrasion against rotator cuff tendon and proximal humerus bone.
        Arthroscopy. 2008; 24: 329-334
        • Curtis A.S.
        • Burbank K.M.
        • Tierney J.J.
        • Scheller A.D.
        • Curran A.R.
        The insertional footprint of the rotator cuff: An anatomic study.
        Arthroscopy. 2006; 22: 603-609
        • Dugas J.R.
        • Campbell D.A.
        • Warren R.F.
        • Robie B.H.
        • Millett P.J.
        Anatomy and dimensions of rotator cuff insertions.
        J Shoulder Elbow Surg. 2002; 11: 498-503
        • Meier S.W.
        • Meier J.D.
        Rotator cuff repair: The effect of double-row fixation on three-dimensional repair site.
        J Shoulder Elbow Surg. 2006; 15: 691-696
        • Kim D.H.
        • ElAttrache N.S.
        • Tibone J.E.
        • et al.
        Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair.
        Am J Sports Med. 2006; 34: 407-414
        • Park M.C.
        • Cadet E.R.
        • Levine W.N.
        • Bigliani L.U.
        • Ahmad C.S.
        Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques.
        Am J Sports Med. 2005; 33: 1154-1159
        • Park M.C.
        • ElAttrache N.S.
        • Tibone J.E.
        • Ahmad C.S.
        • Jun B.J.
        • Lee T.Q.
        Part I: Footprint contact characteristics for an arthroscopic transosseous-equivalent rotator cuff repair technique.
        J Shoulder Elbow Surg. 2007; 16: 461-468
        • Pauly S.
        • Kieser B.
        • Schill A.
        • Gerhardt C.
        • Scheibel M.
        Biomechanic comparison of 4 double-row suture bridging rotator cuff repair techniques using different medial-row configurations.
        Arthroscopy. 2010; 26: 1281-1288
        • Ma C.B.
        • Comerford L.
        • Wilson J.
        • Puttlitz C.
        Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation.
        J Bone Joint Surg Am. 2006; 88: 403-410
        • Park M.C.
        • Idjadi J.A.
        • ElAttrache N.S.
        • Tibone J.E.
        • McGarry M.H.
        • Lee T.Q.
        The effect of dynamic external rotation comparing 2 footprint-restoring rotator cuff repair techniques.
        Am J Sports Med. 2008; 36: 893-900
        • Burkhart S.S.
        • Denard P.J.
        • Obopilwe E.
        • Mazzocca A.D.
        Optimizing pressurized contact area in rotator cuff repair: The diamondback repair.
        Arthroscopy. 2012; 28: 188-195
        • Mazzocca A.D.
        • Bollier M.J.
        • Ciminiello A.M.
        • et al.
        Biomechanical evaluation of arthroscopic rotator cuff repairs over time.
        Arthroscopy. 2010; 26: 592-599
        • Ahmad C.S.
        • Stewart A.M.
        • Izquierdo R.
        • Bigliani L.U.
        Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques.
        Am J Sports Med. 2005; 33: 1667-1671
        • Ahmad C.S.
        • Vorys G.C.
        • Covey A.
        • Levine W.N.
        • Gardner T.R.
        • Bigliani L.U.
        Rotator cuff repair fluid extravasation characteristics are influenced by repair technique.
        J Shoulder Elbow Surg. 2009; 18: 976-981
        • Nassos J.T.
        • ElAttrache N.S.
        • Angel M.J.
        • Tibone J.E.
        • Limpisvasti O.
        • Lee T.Q.
        A watertight construct in arthroscopic rotator cuff repair.
        J Shoulder Elbow Surg. 2012; 21: 589-596
        • Sugaya H.
        • Maeda K.
        • Matsuki K.
        • Moriishi J.
        Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation.
        Arthroscopy. 2005; 21: 1307-1316
        • Shin S.J.
        • Oh J.H.
        • Chung S.W.
        • Song M.H.
        The efficacy of acromioplasty in the arthroscopic repair of small- to medium-sized rotator cuff tears without acromial spur: Prospective comparative study.
        Arthroscopy. 2012; 28: 628-635
        • MacDonald P.
        • McRae S.
        • Leiter J.
        • Mascarenhas R.
        • Lapner P.
        Arthroscopic rotator cuff repair with and without acromioplasty in the treatment of full-thickness rotator cuff tears: A multicenter, randomized controlled trial.
        J Bone Joint Surg Am. 2011; 93: 1953-1960
        • Milano G.
        • Grasso A.
        • Salvatore M.
        • Zarelli D.
        • Deriu L.
        • Fabbriciani C.
        Arthroscopic rotator cuff repair with and without subacromial decompression: A prospective randomized study.
        Arthroscopy. 2007; 21: 81-88
        • Kartus J.
        • Kartus C.
        • Rostgard-Christensen L.
        • Sernert N.
        • Read J.
        • Perko M.
        Long-term clinical and ultrasound evaluation after arthroscopic acromioplasty in patients with partial rotator cuff tears.
        Arthroscopy. 2006; 22: 44-49
        • Galatz L.M.
        • Ball C.M.
        • Teefey S.A.
        • Middleton W.D.
        • Yamaguchi K.
        The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears.
        J Bone Joint Surg Am. 2004; 86: 219-224
        • Boileau P.
        • Brassart N.
        • Watkinson D.J.
        • Carles M.
        • Hatzidakis A.M.
        • Krishnan S.G.
        Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal?.